  ander son p ow er pr oducts ? ? spec pak ? solar power | wind power | dc lighting | inverters | micro inverters | battery back up led lighting | solar panels | combiner boxes | hydro-electricity | harsh environments sealed power for environmental connections
www.andersonpower.com - 2 - configurable to 1000 volts 1 - chemical & uv resistant ruggedized shells ? wire to wire configurations ? panel mount configurations 2 - touch safe housings (ul1977, section 10.2) 3 - ip68 interfacial sealing gasket 4 - locking latch (nec 2008, section 690.33c) 5 - power contacts (up to 4) and / or signal contacts (up to 16) 6 - uses industry standard sealing components (pg gland compatible - size 16) 7 - first mate / last break ground contacts (nec 2008, section 690.33d) 8 - housing colors to match wire colors for ease of assembly 9 - unlocking tool rugged and sealed (ip68) plugs and receptacles for use with app ? powerpole ? signal, power & ground contacts & housings app ? s solar spec pak ? connector series uses rugged and environmentally sealed (ip68) shells to protect industry leading app ? powerpole ? contacts and housing. customer configured solar spec pak ? is designed specifically to meet the requirements of the photovoltaic industry conforming to nec 2008 requirements for first make/last break ground and a locking feature that require a tool to unlock. its also the first multipole connector to conform to ul 6703a. the adaptive design lends itself towards use in other markets including wind power, fuel cells, mass transporta - tion, off-road vehicles, agricultural equipment, oil and petro chemical exploration and many more. the core app ? powerpole ? technology within the spec pak ? is proven reliable and cost effective. the broad selection of touch safe, color-coded powerpole ? housings with power, signal and ground contacts accept a broad range of wire gauges, #24 to #10 awg (0.25 to 4.0 mm2), giving users thousands of flexible design solutions in a single interconnect. 4 2 3 5 6 8 1 7 9
specifcations www.andersonpower.com - 3 - electrical current rating (amprese) ul 1977 - 15 to 40 40 7 ul 6703a - 20 - - csa (30c rise) - 10 to 26 35 5 voltage rating ul 1977 (ac/dc) - 600 600 300 ul 6703a (ac) - 600 600 - iec 60664 (ac/dc) - 1,000 - - dielectric withstanding (ac/dc) - 2,200 2,200 1,600 contact resistance (average) - 525 525 - hot plug 2 (ul 1977) 250 cycles at 120v - 30 30 - mechanical environmental seal ip rating ip68 - - - ul 50 sec 36 pass - - - wire size - 20 to 10 awg 14 to 10 awg 24 to 20 awg - 0.5 to 4.0 mm2 1.5 to 4.0 mm2 0.25 to 0.5 mm2 operating temperature ul 1977 -40 to 105c -20 to 105c -20 to 105c -20 to 105c -40 to 221f -4 to 221f -4 to 221f -4 to 221f ul 6703a -35 to 65c - - - -31 to 149f - - - mating cycles (no load) tin - 1,500 1,500 - silver - 10,000 - - gold - - - 5,000 latch mating cycles 200 - - - lock (nec 2008 sec 690.33c) pass - - - contact retention force (lbf) - 25.0 25.0 12.0 (n) - 111.0 111.0 53.0 insertion force (lbf) - - 3.0 4.5 max (n) - - 13.3 20.0 max touch safe (ul 1977 sec 10.2) - pass - - mechanical shock (50g) mil standard 202 213 cond a pass - - vibration (10g) mil standard 202 204 cond a pass - - materials shell / housing pbt / pc pc pc pbt / pc powerpole ? holder pc - - - latch ppe - - - flammability (ul 94) v0 v0 v0 v0 weatherability (ul 764c) f1 - - - -35c impact test (ul 6703a sec 30) pass - - - thermal cycle test (ul 6703a sec 35) pass - - - humidity cycle test (ul6703a sec 36) pass - - - contacts base - copper alloy copper alloy copper alloy plating - tin or silver tin or silver gold, 50 notes: 1. ppmx housing holds up to 2 pin and 2 sockets. 2. hot plug testing completed using individual powerpole ? housings and contacts, not installed in spec pak ? shells. for other industry test and/or agency approvals, contact customer service. ............................. spec pak ? shells used with .......................... powerpole ? power powerpole ? ground ppmx 1 signal contacts & housings contacts & housings contacts & housings spec pak ? shell (1327fp series) (1827 series) (4800 series)
part number confgurator part number plan www.andersonpower.com - 4 - ordering information p k 2 - 050 b04 p = solar k = black 1 = inline receptacle 050 = 50 mm - 4 pole shell b04 = pp15/45 housing (any type), 4 pole spec pak ? 2 = panel mount receptacle 6 = straight plug 9 = panel mount receptacle cover 9r = inline receptacle cover 9p = plug cover spec pak ? series shell color shell style shell size insert arrangement (1 fixed character) (1 character) (1 character) dash (mm) (3 characters) (3 characters) spec pak ? shell kits part number description pk6-050b04 plug shell kit - plug shell (includes interfacial sealing gasket) - powerpole ? holder for plug PK2-050B04 panel mount receptacle shell kit - panel mount receptacle shell with locking latch - powerpole ? holder for receptacle - panel mount gasket for receptacle pk1-050b04 inline receptacle shell kit - inline receptacle shell with locking latch - powerpole ? holder for receptacle pk9p-050 cover kit for plug - protective sealing (ip68) cover with lanyard - with locking latch pk9-050 cover kit for panel mount receptacle - protective sealing (ip68) cover with lanyard pk9r-050 cover kit for inline receptacle - protective sealing (ip68) cover with lanyard component replacement parts part number description 114805p1 panel mount gasket for receptacle 2-8709p1 4 position solar locking latch pkt-050t01 4 position solar unlocking tool (for use with locking latch) inline receptacle kit panel mount receptacle kit plug kit note: - mounting hardware (4 each - m3 or #4 screws) not included - recommended torque for mounting hardware is 2? to 4 in-lbf (0.28 to 0.45 n) panel mount receptacle shell latch panel mount gasket receptacle powerpole ? holder plug powerpole ? holder plug shell interfacial sealing gasket receptacle powerpole ? holder inline receptacle shell ip68 sealing cover kit latch plug cover receptacle cover
part number plan www.andersonpower.com - 5 - 00 = custom configuration - use next section 01 = 261g2 contact for #10 to #14 awg (4.0 to 1.5 mm2) wire 02 = 200g1l contact for #10 to #14 awg (4.0 to 1.5 mm2) wire 03 = 261g1 contact for #12 to #16 awg (2.5 to 1.0 mm2) wire 04 = 1331 contact for #12 to #16 awg (2.5 to 1.0 mm2) wire 05 = 262g1 contact for #16 to #20 awg (1.0 to 0.5 mm2) wire 06 = 1332 contact for #16 to #20 awg (1.0 to 0.5 mm2) wire 99 = all signal amperage ratings are available on page 9. housing wire protection arrangement contact see pages 6 & 7 for more information see pages 8 & 9 app ? content (4 characters) dash (1 character) (2 characters) dash (3 characters) ps 01 - 0 00 - leave blank 00 = none 00 = none 0 = custom configuration - use next section custom configuration* ps = plastic short 01-99 = varies by gland type a = ac, single phase contact factory pf = plastic with flex spring b = ac, 3 phase, 3 wire pr = plastic right angle c = dc, 2 circuit, 4 wire pm = plastic multi hole d = dc, 2 wire, with ground ct = conduit adapter threaded h = dc, 2 wire, with 8 signal ca = conduit adapter push-in j = ac, single phase, with 4 signal l = dc, 2 wire, with 4 signal n = dc, 2 wire, with ground & 4 signal u = dc, 2 wire x = all signal note: 1. see pg gland charts on page 6 & 7 for details. 2. panel mount receptacle side is always 00 . part numbering notes: 1. to order spec pak ? shell kits only (no internal powerpole ? housings or contacts), use part numbering on page 4 only. plug shell kit example: pk6-050b04. powerpole ? housings, contacts and wire protection may be ordered separately, see pages 6, 7 and 10 for information. 2. to order spec pak ? connectors kits (including internal powerpole ? housings and contacts) use part number plan across the top of pages 4 and 5. standard spec pak ? plug configuration example: pk6-050b04ps01-b01 3. to order a custom configuration which is not listed on page 8 and 9, use custom part number configurator on the app ? website, www.andersonpower.com or contact factory. * custom configuration may not be ul recognized.
wire protection - pg gland www.andersonpower.com - 6 - straight plastic with flex spring - std pack 50 / ul listed straight plastic short thread type - std pack 50 / ul listed specifications washer body seal sealing nut c1 c2 wire protection cable range thread o. d. panel thread length wrench size wrench size designation wire outer dia. c1 mounting hole c2 lock nut sealing nut app ? p/n (4 characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm) ps1p16-10x ps01 11.2 - 5.5 (0.44 - 0.22) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27 ps1p16-14x ps02 14.1 - 8.0 (0.56 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27 wire protection cable range thread o.d. panel thread length wrench size wrench size designation wire outer dia. c1 mounting hole c2 lock nut sealing nut app ? p/n (4 characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm) pr1p16-10x pr01 11.0 - 7.0 (0.43 - 0.28) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 27 pr1p16-13x pr02 13.0 - 8.0 (0.51 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 27 right angle - std pack 50 / ul listed washer body seal claw sealing nut c2 c1 lock nut for pg 16 cable glands lock nut app ? wrench size std. pkg. p/n lock nut (mm) size 124g31 30 50 washer body seal sealing nut c1 c2 wire protection cable range thread o.d. panel thread length wrench size wrench size designation wire outer dia. c1 mounting hole c2 lock nut sealing nut app ? p/n (4 characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm) pf1p16-10x pf01 11.2 - 5.5 (0.44 - 0.22) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 pf1p16-13x pf02 13.8 - 8.0 (0.54 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 notes: 1. for v0 material, contact the factory. spec pak ? connectors are not ul recognized components when used with cable glands that are not ul listed. torque requirement cable gland body to connector shell ? hand tighten until snug, tighten additional 1/8 to 1/4 turn with wrench sealing nut to cable ? hand tighten until snug, tighten additional 1/2 to 3/4 turn with wrench gland styles straight plastic straight plastic with flex spring right angle straight plastic multi-hole straight conduit straight conduit push-in mechanical ip rating ip68 ip68 operating temperature ul 1977 -40 to 105c -31 to 100c -40 to 221f -22 to 212f ul 6703a -35 to 65c - -31 to 149f - thread type pg pg thread size 16 16 flammability (ul 94) v2 1 - weatherability (ul 764c) f1 - material shell nylon pa 66 nylon pa 66 gasket epdm tpe color black black
www.andersonpower.com - 7 - corrugated nylon plastic tubing straight conduit adapter thread type - std pack 50 / not ul listed straight plastic multi-hole type - std pack 50 / not ul listed c1 c2 washer body seal sealing nut corrugated f1 straight conduit push-in type - std pack 50 / not ul listed conduit i. d. conduit o. d. conduit trade std. pkg. app ? p/n mm (in) mm (in) size size (mm) meters (feet) ngn - 12b 11.8 (0.46) 15.8 (0.62) 3/8 od15.8 50 (164) ngn - 14b 13.8 (0.54) 17.8 (0.70) - - 50 (164) ngn - 17b 16.7 (0.66) 21.2 (0.83) 1/2 od21.2 50 (164) ngn - 23b 21.7 (0.85) 28.5 (1.12) 3/4 od28.5 50 (164) wire protection thread o.d. panel thread length wrench size wrench size app ? conduit designation c1 mounting hole c2 lock nut sealing nut conduit trade app ? p/n (4 characters) mm (in) mm (in) mm (in) (mm) (mm) p/n size cap16-15x ca01 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 21 ngn - 12b od15.8 cap16-18x ca02 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 21 - od18.5 cap16-21x ca03 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27 ngn - 17b od21.2 cap16-28x ca04 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 34 ngn - 23b od28.5 for r/a versions contact factory wire protection cable range thread o.d. panel thread length wrench size wrench size designation number wire outer dia. c1 mounting hole c2 lock nut sealing nut app ? p/n (4 characters) of holes mm (in) mm (in) mm (in) mm (in) (mm) (mm) ps2p16-3x pm21 2 3.5 - 2.5 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps2p16-4x pm22 2 4.3 - 3.3 (0.17 - 0.13) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps2p16-6x pm23 2 6.1 - 4.3 (0.24 - 0.17) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps3p16-3x pm31 3 3.6 - 2.6 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps3p16-5x pm32 3 5.2 - 3.5 (0.20 - 0.14) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps4p16-2x pm41 4 2.5 - 1.6 (0.10 - 0.06) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps4p16-3x pm42 4 3.6 - 2.5 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps4p16-4x pm43 4 4.8 - 3.4 (0.19 - 0.13) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps5p16-2x pm51 5 2.1 - 1.3 (0.08 - 0.05) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps5p16-3x pm52 5 3.1 - 2.0 (0.12 - 0.08) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps5p16-4x pm53 5 4.1 - 3.0 (0.16 - 0.12) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps6p16-2x pm61 6 2.0 - 1.3 (0.08 - 0.05) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 ps6p16-3x pm62 6 3.0 - 2.0 (0.12 - 0.08) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27 wire protection max. joint thread o.d panel thread length wrench size app ? conduit designation f1 c1 mounting hole c2 lock nut conduit trade app ? p/n (4 characters) mm (in) mm (in) mm (in) mm (in) (mm) p/n size ct1p16-15x ct01 16.0 (0.63) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 ngn - 12b od15.8 ct1p16-18x ct02 18.3 (0.72) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 ngn - 14b - ct1p16-21x ct03 22.0 (0.87) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 ngn - 17b od21.2 washer body seal c1 c2 tubing cutter app ? p/n description range (mm) tm0002 corrugated plastic tubing cutter up to od 34.5 c1 c2 washer body seal claw sealing nut
standard housing arrangements & contacts www.andersonpower.com - 8 - housing arrangements for power, signal & ground connectors arrangements represent front view of receptacle custom confguration may be created using apps part number confgurator at www.andersonpower.com 1 3 2 7 g 6 f p 1 8 27g a 1 3 2 7 g 7 f p 1 3 2 7 g 6 f p 4827g6 e 1 3 2 7 g 6 f p 1 3 2 7 f p 1827ga a c si n g l e phase with 4 signal dc 2 wire with 4 signal dc 2 wire with ground & 4 signal dc 2 wire all signal l j n 1 3 2 7 g 6 f p e 1 8 27g a 1 3 2 7 g 7 f p 1 3 2 7 g 6 f p 1327fp 1 3 2 7 g 7 f p 1 8 27g a 1 3 2 7 g 6 f p 1 3 2 7 g 6 f p 1 3 2 7 f p 1 3 2 7 f p 1 3 2 7 g 6 f p e 1327fp 1 8 27g a custom configuration a c si n g l e phase ac 3 phase, 3 wire dc 2 circuit, 4 wire dc 2 wire with ground a 0 c b d e = empty 1327 series = power 1827 series = ground 4800 series = signal 4827g6 1327fp 4827g6 4827g6 4827g6 4827g6 x 4827g6 dc 2 wire with 8 signal 4827g6 1 3 2 7 g 6 f p 1 3 2 7 f p h 4827g6 1327g6fp 1327fp e u e notes: 600 volt rating ? ul 1977 - all configurations ? ul 6703a - configuration b ? iec 60664 - all configurations 1000 volt rating ? iec 60664 - configuration u
www.andersonpower.com - 9 - continuous current ratings - power contact code selection holder locations (views) front back front back receptacle plug 2 1 4 3 1 2 3 4 1 2 3 4 2 1 4 3 notes: 1. current ratings under ul1977: ? first number represents current rating per pole for 30c temperature rise (25 / 38) ? second number is the maximum recommended current per pole based on a 25c ambient (25 / 38) (current ratings under ul 6703a, contact the factory) 2. configuration h - n based on signal contacts crimped to #20 awg wire and carrying 1 amp. 3. denotes wire size not appropriate for power contact. 4. shaded boxes are pending. 5. 1827ga housing should be used with 1830g1 or 1830g2 ground contact, depending on primary contacts. all signal housings (4850) available with up to two 4802g3 and two 4803g3 contacts. temperature chart 0 1 0 2 0 3 0 4 0 5 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 spec pak ? (4) pole - temperature rise based on 261g2 contact temperature (c) amperes #10 awg #12 awg #14 awg
individual components www.andersonpower.com - 10 - powerpole ? housings & contacts note: ld - low detent 15/45 powerpole ? contacts loose piece package quantity: standard, 200 pieces - bulk, 5,000 pieces standard bulk part number part number description #16 to #20 awg (1.0 to 0.5 mm2) 1332 1332-bk individual-ld-silver plate 262g1-lpbk - singulated reel-ld-tin plate 262g2-lpbk - singulated reel-ld-silver plate #12 to #16 awg (2.5 to 1.0 mm2) 1331 1331-bk individual-ld-silver plate 261g1-lpbk - singulated reel-ld-tin plate #10 to #14 awg (4 to 1.5 mm2) 261g2-lpbk - singulated reel-ld-tin plate 261g3-lpbk - singulated reel-ld-silver plate 200g1l-lpbk - superflex, sing. reel-ld-tin plate reel - 15/45 powerpole ? contacts package quantity 5,000 part number description #16 to #20 awg (1.0 to 0.5 mm2) 262g1 reel-ld-tin plate 262g2 reel-ld-silver plate #12 to #16 awg (2.5 to 1.0 mm2) 261g1 reel-ld-tin plate #10 to #14 awg (4 to 1.5 mm2) 261g2 reel-ld-tin plate 261g3 reel-ld-silver plate #10 to #14 awg (6 to 1.5mm2) 200g1l superflex, reel-ld-tin plate fingerproof pp15/45 housing only package quantity: standard, 200 pieces - bulk, 2,500 pieces standard bulk part number part number description 1327fp 1327fp-bk red housing 1327g5fp 1327g5fp-bk green housing 1327g6fp 1327g6fp-bk black housing 1327g7fp 1327g7fp-bk white housing 1327g8fp 1327g8fp-bk blue housing 1327g16fp 1327g16fp-bk yellow housing standard pp 15/45 housing only package quantity: standard, 200 pieces - bulk, 2,500 pieces standard bulk part number part number description 1327 1327-bk red housing 1327g5 1327g5-bk green housing 1327g6 1327g6-bk black housing 1327g7 1327g7-bk white housing 1327g8 1327g8-bk blue housing 1327g16 1327g16-bk yellow housing 1327g17 1327g17-bk orange housing 1327g18 1327g18-bk gray housing 1327g21 1327g21-bk brown housing 1327g22 1327g22-bk pink housing 1327g23 1327g23-bk purple housing premate ground pp15/45 housing only package quantity: standard, 200 pieces - bulk, 2,500 pieces standard bulk part number part number description 1827ga 1827ga-bk green housing premate ground contacts loose piece package quantity 200 part number description #10 to #14 awg (4 to 1.5 mm2) 1830g1-lpbk singulated-ld-tin plate 1830g2-lpbk singulated-ld-silver plate reel package quantity 5,000 part number description #10 to #14 awg (4 to 1.5 mm2) 1830g1 reel-ld-tin plate 1830g2 reel-ld-silver plate individual singulated open barrel on a reel contact styles
www.andersonpower.com - 11 - ppmx (4800 series) housing & contacts pp15/45 powerpole ? housing styles * all hand and pneumatic tools for use with loose piece contacts only. all reeled contacts can be ordered singulated, (loose piece) with the suffix - lpbk ** 1309g8 is a hand tool kit- includes dies and locators to make up 1309g2, 1309g3, &1309g6 application tooling - powerpole ? 15 / 45 contacts powerpole ? fingerproof housing rib feature powerpole ? standard housing closed nose powerpole ? premate ground housing open nose ppmx housing 2 socket & 2 pin contacts open nose 1327fp series 1327 series 1827 series 4800 series l o o se p i e ce t i n p a r t n u m b e r l o o se p i e ce s i l ve r p a r t n u m b e r h a n d t o o l* o r p n e u m a t i c t o o l* r e e l e d t i n p a r t n u m b e r r e e l e d s i l ve r p a r t n u m b e r a t s a p p l i ca t o r n / a 1 3 3 2 n / a n / a n / a n / a 1 3 3 1 n / a n / a n / a 2 6 2 g 1 - l p b k 2 6 2 g 2 - l p b k 2 6 1 g 1 2 6 2 g 2 1 3 8 5 5 2 0 2 0 0 g 2 l - l p b k 2 0 0 g 4 l - l p b k 2 0 0 g 2 l 2 0 0 g 4 l t b d 2 6 1 g 1 - l p b k 2 6 1 g 4 - l p b k 2 6 1 g 1 2 6 1 g 4 1 3 8 5 5 2 0 2 6 1 g 2 - l p b k 2 6 1 g 3 - l p b k 2 6 1 g 2 2 6 1 g 3 1 3 8 5 4 5 8 2 0 0 g 1 l - l p b k 2 0 0 g 3 l - l p b k 2 0 0 g 1 l 2 0 0 g 3 l 1 3 8 5 4 6 0 1 8 3 0 g 1 - l p b k 1 8 3 0 g 2 - l p b k 1 8 3 0 g 1 1 8 3 0 g 2 1 3 8 5 4 6 0 1 3 6 7 g 1 n / a 1 3 0 9 g 3 o r 1 3 0 9 g 8** 1 3 0 9 g 6 o r 1 3 0 9 g 8** 1 3 0 9 g 2 o r 1 3 0 9 g 8** c o n t a ct p a r t n u m b e r a p p ? h a n d t o o l o r m i l s t d . h a n d t o o l ( a p p p a r t # ) + p o si t i o n e r + p n e u m a t i c t o o l f o r l o ca t o r / t u r r e t 4 8 0 2 g 3 4 8 0 3 g 3 n o m i l s t d . ( t l 0 0 05) t p 0 0 0 1 p m 1 0 0 0 g 1 m 2 2 5 2 0 / 1 - 0 1 ( t m 0 0 0 1 ) application tooling - ppmx contacts ppmx signal housing package quantity standard, 25 pieces - bulk, 1,000 pieces standard bulk part number part number description 4827g6 4827g6-bk black two piece housing ppmx signal contacts package quantity standard, 50 pieces - bulk, 2,000 pieces loose piece #20 to #24 awg (0.50 to 0.25 mm2) standard bulk part number part number description 4802g3 4802g3-bk socket, gold, 50 micro-inches 4803g3 4803g3-bk pin, gold, 50 micro-inches ppmx signal housing & contact kits package quantity standard, 100 pieces 1 black two piece housing, 2 male contacts, 2 female contacts standard bulk part number part number description 4850g6 - 50 micro-inches gold plated contacts - pin & socket
www.andersonpower.com - 12 - dimensions all data subject to change without notice patents with patents pending 15145 ds-solarspak rev 02 headquarters: anderson power products?, 13 pratts junction road, sterling, ma 01564-2305 usa t:978-422-3600 f:978-422-0128 europe: anderson power products? ltd., unit 3, europa court, europa boulevard, westbrook, warrington, cheshire, wa5 7tn united kingdom t: +44 (0) 1925 428390 f: +44 (0) 1925 520203 asia / pacific: ideal anderson asia pacifc ltd., unit 922-928 topsail plaza, 11 on sum street, shatin n.t., hong kong t:+(852) 2636 0836 f:+(852) 2635 9036 china: ideal anderson technologies (shenzhen) ltd., block a8 tantou western industrial park, songgang baoan district, shenzhen, pr. china 518105 t: +(86) 755 2768 2118 f: +(86) 755 2768 2218 taiwan: ideal anderson asia pacifc ltd., taiwan branch, 4f.-2, no.116, dadun 20th st., situn district, taichung city 407, taiwan (r.o.c.) t: +(886) 4 2310 6451 f:+(886) 4 2310 6460 www.andersonpower.com [ 53.6 ] 2.11 [ 68.3 ] 2.69 pg 16 female thread [ 40.4 ] 1.59 interfacial gasket [ 33.7 ] 1.33 [ 68.3 ] 2.69 [ 68.6 ] 2.70 [ 35.4 ] r1.36 sweep of latch [ 123.6 ] 4.87 [ 38.7 ] 1.52 [ 29.4 ] 1.16 top view front view side view mated side view panel cut out front view side view back view top view front view side view mated side view ps - plastic ct - threaded conduit ca - push-in conduit pf - plastic pr - right angle short adapter adapter flex pg front view side view front view side view plug 4 position for pp15/45 housings panel mount receptacle 4 position for pp15/45 housings inline receptacle 4 position for pp15/45 housings pg glands receptacle cover kit plug cover kit [ 50.2 ] 1.98 [ 38.2 ] 1.50 [ 38.4 ] 1.51 [ 33.7 ] 1.33 [ 54.1 ] 2.13 [ 23.2 ] 0.91 [ 95.1 ] 3.74 [ 43.9 ] 1.73 [ 33.0 ] 1.30 [ 33.0 ] 1.30 [ 50.2 ] 1.98 [ 44.5 ] 1.75 [ 44.5 ] 1.75 [ 55.6 ] 2.19 [ 44.5 ] 1.75 [ 50.3 ] 1.98


▲Up To Search▲   

 
Price & Availability of PK2-050B04

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X